60-Hz AC EMF Guidelines Established by International Health and Safety Organizations
| Organization | Electric Field | Magnetic Field |
|---|---|---|
|
American Conference of Governmental and Industrial Hygienists (ACGIH) (occupational) |
25 kV/ma |
10,000 mGa 1,000 mGb |
|
International Commission on Non-Ionizing Radiation Protection (ICNIRP) (general public) |
4.2 kV/mc | 2,000 mGc |
|
International Commission on Non-Ionizing Radiation Protection (ICNIRP) (occupational) |
8.3 kV/mc | 10,000 mGc |
|
International Committee on Electromagnetic Safety (ICES) Standard C95.6 (general public) |
5.0 kV/md | 9,040 mGd |
|
Institute of Electrical and Electronics Engineers (IEEE) Standard C95.6 (occupational) |
20.0 kV/md | 27,100 mGd |
Notes:
AC = Alternating Current; EMF = Electric and Magnetic Field; Hz = Hertz; kV/m = Kilovolts Per Meter; mG = Milligauss.
(a) The ACGIH guidelines for whole-body exposure for the general worker (ACGIH, 2025 225-6059).
(b) The ACGIH guidelines for workers with cardiac pacemakers (ACGIH, 2025 225-6059).
(c) ICNIRP (2010 211-0614).
(d) ICES (2020 221-6379).